Oxygen Generator

Oxygen Generator

1. Nebulizer (Atomizer) Please be advised that a maintenance alarm should be set to go off after 3000 hours of operation. An alarm will sound when the internal system temperature exceeds 50 degrees, indicating a high temperature. A fingertip pulse oximeter is provided to monitor the oxygen...
Send Inquiry
Product Introduction

image001

1. Nebulizer (Atomizer)

Please be advised that a maintenance alarm should be set to go off after 3000 hours of operation.

An alarm will sound when the internal system temperature exceeds 50 degrees, indicating a high temperature.

A fingertip pulse oximeter is provided to monitor the oxygen saturation of patients on-site. This device, known as an SPO2 pulse oximeter, allows for convenient and efficient monitoring of a patient's oxygen levels. With this technology, healthcare providers can easily assess the patient's oxygen saturation levels and make necessary adjustments to treatment if needed. This tool is essential in ensuring accurate and timely monitoring of a patient's oxygen levels.

The LCD display provides information such as the present time, present working time, and accumulated time.

 

Note

To maintain the proper functioning of oxygen concentrators, it is essential to regularly clean the filter cotton. The first layer of filter cotton should be cleaned or replaced after the oxygen generator has been in use for 200 hours, while the second layer should undergo the same maintenance procedure after 500 hours of operation. Additionally, it is recommended to clean the machine housing every one or two months using a soft towel and mild detergent. Remember to power off the device before wiping the housing and ensure it is thoroughly dried with a dry towel afterwards. Following these maintenance guidelines will help ensure the reliable performance of the oxygen concentrator.

 

Technical Parameter

Weight

21.3Kg±5%

Size

380mm*355mm*610mm

Input power

350VA

Average sound pressure level

≤60dB (A)

Maximum recommended flow

5L/min

If the nominal pressure at the outlet is increased to 7kpa, it would cause a change in flow. This change in flow would be a direct result of the increased pressure exerted on the outlet, which could potentially lead to a faster flow. It is important to note that this change in flow would depend on various factors such as the size and structure of the outlet, as well as the viscosity of the liquid flowing through it. Therefore, it is crucial to take into account these variables when considering the impact of increasing the outlet nominal pressure.

≤10%

The recommended maximum flow for oxygen concentration should not be exceeded, ensuring a sufficient supply.

≥90% (V/V)

Oxygen outlet pressure

30kPa ~ 60kPa

Atomization gasflow

should be more than 10L/min

Atomizing pressure range

70kPa ~ 170kPa

Applicable powersupply

AC220V / 50Hz

 

Packing
  • Carton box

  • Qty/Ctn: 1pcs/carton

  • Carton Size: H720*W460*L470mm

  • MOQ: 50 pcs

product-750-850
product-750-850

 

Loading Quantity
  • 180pcs/20GP
  • 380pcs/40GP
  • 430pcs/40HQ

 

Countries and Regions: Peru, Chile, Bolivia, Venezuela, Colombia, Ecuador, Mexico, Argentina, Ethiopia, Armenia and various border zones in highland areas such as the Sino-India border plateau.

 

Hot Tags: oxygen generator, China oxygen generator manufacturers, suppliers, factory